What happens?
When generating the documentation or generating the reports, the message Unable to generate the report is displayed.
Why does it happens?
The situation can occur because the items in the 3D space are not registered correctly.
What to do?
First, identify the type of registration of the composed panel:
1. With the BuilderOperation attribute
2. Without the BuilderOperation attribute
With the BuilderOperation attribute
1. Access the menu Registry – Modules;
2. Locate the registration of the composed panel in question;
3. In the parent item (module), access the Attributes tab and check if the BuilderOperation attribute has the value Operation. Also check if it has the ComposedReport attribute with a value of True. If not, apply it;
4. Then, access the aggregates of Composed panel and check if the Component attribute is applied with True value. Also check if the ComposedReport attribute is applied with true value. If not, apply the attributes or change the value.
IMPORTANT: apply the ComposedReport attribute as true only on aggregates that will be displayed in the Composed panelReport.
Without the BuilderOperation attribute
Why does this situation occur?
1. The parent item (composed panel) does not have the Composed attribute;
2. The aggregates of tamburato do not have the Composed and Component attributes with a True value.
What to do?
1. Access the menu Register – Modules;
2. Locate the registration of the tamburato in question
3. In the parent item (module), access the Attributes tab and check if it has the Composed attribute with a True value and the Component attribute with a True value. If not, apply them;
4. Then, access the aggregates of Composed panel and check if the Component attribute is applied with a True value. If not, apply the attribute or change the value.
For more information about the registration of Composed Panel, access here.