Available from version:
- Plugin Builder 1.60.0.15 or higher
IMPORTANT: For Evolution 7401-7402 and 7405.
The value to conference of measure X refers to relative distance from the end of the part where the operations contained in this region will be compensated for as a function of the actual larger part size.
By default, the field has the value 0 (zero). Can be set to any no negative integer or decimal value.
- Example: Applied value of 150:
Value setting
In Builder configurations, the configuration of this functionality is displayed as follows:
IMPORTANT:
- If a valid value other than 0 (zero) is entered, one more command is generated in the programs.
- If the value is 0 (zero) no commands are added to programs.
Command
The generated command is CALL HH MegQuote (VAL=X), where X is the value entered in the field.
- Example:
If field X has set the value 33, the command will be generated CALL HH MegQuote (VAL=33).